Evaluation of implant’s primary stability using Densah bur versus expander in patients with missing maxillary premolar (A randomized clinical trial)

Document Type : Original Article

Authors

1 Implantology department, Faculty of dentistry, Cairo University, Egypt

2 Associate Professor of Removable Prosthodontics, Faculty of Dentistry, Cairo University.

Abstract

Aim: This study aimed to evaluate implant primary stability using Densah bur in comparison with expanders in maxillary premolar area. Material and methods: This study was conducted on twenty patients. The patients were divided into two equal groups. Each patient received one implant at the edentulous site of missing first or second maxillary premolar. One group received implants after using Densah bur, while the other group received implants after using screw expander. After implant placement, Smart peg was placed on implant and Ostell was used to record ISQ. Implant stability was measured intraoperative and at weeks 2, 4, 6, and 8 for both groups. The collected results were tabulated and statistically analyzed. Results: The study results showed there was no statistically significant difference between (Expander) and (Densah bur) groups in ISQ reading except at surgery and week two where the highest mean value was found in (Expander) group, while the least mean value was found in (Densah bur) group. Conclusion: Within the limitation of this study, Densah bur enabled successful implant insertion with acceptable primary stability in the resorbed maxillary premolar area. Moreover, the Densah bur can be used in a faster manner.