Introduction: The accuracy of different scanning techniques and intra-oral scan bodies (ISBs) in allocating the position of dental implants in complete overdenture digital impression has been questioned, this work compared it to conventional impression in situation where 4 parallel implants were used to simulate implant-supported overdenture situations in an in-vitro setting. Materials and methods: A conventional and digital impressions using ISBs and 5 different scanning techniques were made of a study model having 4 parallel implants at teeth sites 36, 33, 43, and 46 which were designated as A, B, C, and D respectively. The resulting stone cast and digital impressions virtual casts were compared for linear deviations between the implant sites using a digital caliper versus computerized measurements, and for surface mismatching using a computerized superimposition process of the stone model scan and virtual models. The linear deviations measurements were statistically analyzed using the paired t test, and the horizontal deviations were statistically analyzed using the Kruskal Wallis test. Results: Comparison of the linear measurements on the stone cast and virtual models detected significant differences in the second and third sextants of the dental arch with techniques I and IV, while superimposition horizontal deviations detected significant differences at implant positions C and D also in techniques I and IV. Conclusions: Virtual models generated from full arch digital impressions using scan bodies and scanning techniques II, III, and V had similar accuracy to stone models developed from conventional elastomeric impressions.
Alkhodary, M. (2022). Accuracy of implant supported overdenture digital impression utilizing scan bodies and different scanning techniques: an in-vitro and in-silico study. Egyptian Dental Journal, 68(2), 1675-1684. doi: 10.21608/edj.2022.118309.1966
MLA
Mohamed Ahmed Alkhodary. "Accuracy of implant supported overdenture digital impression utilizing scan bodies and different scanning techniques: an in-vitro and in-silico study". Egyptian Dental Journal, 68, 2, 2022, 1675-1684. doi: 10.21608/edj.2022.118309.1966
HARVARD
Alkhodary, M. (2022). 'Accuracy of implant supported overdenture digital impression utilizing scan bodies and different scanning techniques: an in-vitro and in-silico study', Egyptian Dental Journal, 68(2), pp. 1675-1684. doi: 10.21608/edj.2022.118309.1966
VANCOUVER
Alkhodary, M. Accuracy of implant supported overdenture digital impression utilizing scan bodies and different scanning techniques: an in-vitro and in-silico study. Egyptian Dental Journal, 2022; 68(2): 1675-1684. doi: 10.21608/edj.2022.118309.1966